Horizontal Specs & Options

TITAN® is now available in multiple sizes and configurations. All TITAN® models are designed for ease of installation and cost-effective transport.

View Imperial Measurements

Model H2 H4 H6 H8 H10
Hearth Gross Capacity, lbs 2000 4000 6000 8000 10,000
Effective Work Area, inches (W x H x D) 18 x 18 x 24 24 x 28 x 48 36 x 36 x 48 48 x 48 x 72 60 x 60 x 72
Work Zone, ft3 4.5 16 36 96 150
Quench Pressure 2 bar 2 bar 2 bar 2 bar 2 bar
End Elements N/A N/A N/A Option Option
Footprint, inches (W x D) 90 x 160 180 x 180 180 x 180 210 x 220 240 x 240
Power Requirements (AMPS), 460 Volts, Basic Furnace 90 250 300 475 600
Water cooling requirements, gpm @ 40 psi 80 200 200 300 400
Fits in one standard shipping container
Shipping weight (furnace only), lbs 12000 28000 29000 35000 41000
Click thumbnail to enlarge:

All dimensions and specifications are approximations and for reference only

View Metric Measurements

Model H2 H4 H6 H8 H10
Hearth Gross Capacity, kg 900 1800 2700 3600 4500
Effective Work Area, mm (W x H x D) 455 x 455 x 610 610 x 710 x 1220 915 x 915 x 1220 1220 x 1220 x 1830 1525 x 1525 1830
Work Zone, m3 0.13 0.45 1.02 2.72 4.25
Quench Pressure 2 bar 2 bar 2 bar 2 bar 2 bar
End Elements N/A N/A N/A Option Option
Footprint, mm (W x D) 2300 x 4100 4600 x 4600 4600 x 4600 5350 x 5600 6100 x 6100
Power Requirements (AMPS), 380/400 Volts, Basic Furnace 105 300 350 550 700
Water cooling requirements, l/m @ 275 kPa 300 800 800 1150 1500
Fits in one standard shipping container
Shipping weight (furnace only), kg 5500 12700 13200 16300 18600
Click thumbnail to enlarge:

All dimensions and specifications are approximations and for reference only

View Imperial Measurements

Model H2 H4 H6 H8 H10
Hearth Gross Capacity, lbs 2000 4000 6000 8000 10,000
Effective Work Area, inches (W x H x D) 18 x 18 x 24 24 x 28 x 48 36 x 36 x 48 48 x 48 x 72 60 x 60 x 72
Work Zone, ft.3 4.5 16 36 96 150
Quench Pressure 12 bar 12 bar 12 bar 6 bar 6 bar
End Elements N/A N/A N/A Option Option
Footprint, inches (W x D) 90 x 169 180 x 180 180 x 180 220 x 220 250 x 240
Power Requirements (AMPS), 460 Volts, Basic Furnace 150 300 400 500 600
Water cooling requirements, gpm @ 40 psi 150 275 375 450 550
Fits in one standard shipping container
Shipping weight (furnace only), lbs 13000 29500 30500 38000 44000
Click thumbnail to enlarge:

All dimensions and specifications are approximations and for reference only

View Metric Measurements

Model H2 H4 H6 H8 H10
Hearth Gross Capacity, kg 900 1800 2700 3600 4,500
Effective Work Area, mm (W x H x D) 455 x 455 x 610 610 x 710 x 1220 914 x 914 x 1220 1220 x 1220 x 1830 1525 x 1525 x 1830
Work Zone, m3 0.13 0.45 1.02 2.72 4.25
Quench 12 bar 12 bar 12 bar 6 bar 6 bar
End Elements N/A N/A N/A Option Option
Footprint, mm (W x D) 2235 x 4013 4572 x 4394 4572 x 4394 6000 x 6000 6350 x 6100
Power Requirements (AMPS), 380/400 Volts, Basic Furnace 175 350 475 600 700
Water cooling requirements, l/m @ 275 kPa 570 1040 1420 1700 2080
Fits in one standard shipping container
Shipping weight (furnace only), kg 5900 13400 13800 17200 20,000
Click thumbnail to enlarge:

All dimensions and specifications are approximations and for reference only
The versatile Titan vacuum furnace offers multiple standard options that allow heat treaters to enhance the system to their specific needs and still stay within their budget.

To learn about custom options, contact your Ipsen representative.

Click any image below to see a larger view:
High Vacuum

- Diffusion Pump & High Vacuum Valve
- Holding Pump
- Piping & Valving
Water

- Single closed-loop system
- 350 gallon reservoir tank
- Pump station
- Type 2 furnaces only
Metal Hot Zone

- Molybdenum and stainless steel shields
- Molybdenum hearth posts and rails
- Stainless steel frame
Power

- 220-460 Volts
- 50/60 HZ
- 3 Phase
Loader

- 3000 lbs capacity
- Electric lift Type 2 - Manual lift Type 4 or 6
- Built in Charger
Backfill Reservoir

- ASME code tank
- Horizontal or vertical mount
- Includes pressure guage, check valve and ball valve
Expert Controls

- Interactive program generation
- Visualization of load configuration
- Integrated time temperature transformation (TTT) diagrams
Parts

- Consumable and preventative maintenance items to help ensure equipment uptime
Uniformity Fixture

- Designed for the TITAN® hot zone work area
- RA330 material
- Furnished less thermocouples
Convection

- Shorter cycle times
- Convection heating to 1,600°F, 2-bar max